博科交换机6510上电后所有端口亮橙色解决办法
故障現有如圖:
兩個交換機的狀態如下:
----------------------------------------------------------------
SW6510:FID128:admin> switchshow ##上面故障交換機
switchName: SW6510
switchType: 109.1
switchState: Offline (Persistent) ##故障交換機這里顯示離線
switchMode: Native
switchRole: Disabled
switchDomain: 1 (unconfirmed)
switchId: fffc01
switchWwn: 10:00:c4:f5:7c:aa:a1:27
zoning: OFF
switchBeacon: OFF
FC Router: OFF
HIF Mode: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: N o, Address Mode 0]
Index Port Address Media Speed State Proto
==================================================
SW6510:FID128:admin> switchshow ##下面正常交換機
switchName: SW6510
switchType: 109.1
switchState: Online ##正常交換機這里顯示在線
switchMode: Native
switchRole: Principal
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:88:94:71:3f:a7:7d
zoning: OFF
switchBeacon: OFF
FC Router: OFF
HIF Mode: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: N o, Address Mode 0]
Index Port Address Media Speed State Proto
==================================================
故障處理方法
登錄交換機執行下面兩個命令
SW6510:FID128:admin> switchcfgpersistentenable ##第一條命令,使用switchcfgpersistentenable將switch的persisten狀態設置為enable,這樣下次重啟后,switch的狀態是enable。
Switch's persistent state set to 'enabled' ##已經提示為激活
SW6510:FID128:admin>switchenable ##第二條命令,這條命令不執行應該也可以,這條命令是啟用交換機
網上說出現這個的原因如下:
switchState: Offline (Persistent),說明您交換機狀態不對,需要使用命令switchcfgpersistentenable開啟端口即可,出現這種情況很有可能是異常下電了光交,在上電后可能會概率導致交換機進入persistentdisable狀態。
總結
以上是生活随笔為你收集整理的博科交换机6510上电后所有端口亮橙色解决办法的全部內容,希望文章能夠幫你解決所遇到的問題。