Innovus中如何验证低功耗设计
Innovus中如何驗(yàn)證低功耗設(shè)計(jì),針對(duì)這個(gè)問題,這篇文章詳細(xì)介紹了相對(duì)應(yīng)的分析和解答,希望可以幫助更多想解決這個(gè)問題的小伙伴找到更簡(jiǎn)單易行的方法。
此處論及的低功耗設(shè)計(jì)是指帶IEEE1801 或CPF 的設(shè)計(jì),即有多個(gè)電壓域的設(shè)計(jì),對(duì)于這樣的設(shè)計(jì),power mesh 跟placement 做完后,通常需要檢查:
-
placement 是否遵照了power intent 的需求,把對(duì)應(yīng)的cell 擺放在了對(duì)應(yīng)的電壓域中;
-
如何report 某個(gè)instance 或某個(gè) power domain 的低功耗信息;
-
如何對(duì)Power Grid 進(jìn)行check, 如missing vias / straps.
Innovus 提供了如下三個(gè)強(qiáng)大的命令來(lái)完成對(duì)應(yīng)的check:
-
verifyPowerDomain
-
reportPowerDomain
-
verifyPowerVia
verifyPowerDomain
可以用命令 "verifyPowerDomain-bind" 來(lái)檢查是否所有的cell 都被link 到了對(duì)應(yīng)的庫(kù)上。
可以用命令 "verifyPowerDomain -place" 來(lái)檢查cell 和power domain placement 的問題,如power domain 是否有overlap, cell 是否放入了正確的power domain.
reportPowerDomain
用命令"reportPowerDomain" 可以報(bào)出如下信息:
-
Power domain name
-
Power domain bounding box
-
Timing library
-
Mingap
-
Route search (RS) extension
-
Row type and spacing
-
Instance specific PD information
-
Whether PD is always-on
用命令 "reportPowerDomain -bindLib -powerDomainPD_name" 來(lái)check 指定power domain 中各instance 對(duì)應(yīng)的timing library.
用命令"reportPowerDomain -inst $your_instance" 來(lái)check 指定instance 的power domain 信息。
reportPowerDomain 還有許多option, 如-shifter/ -isoInst/ -pgNet, 分別可以用于check 指定power domain 中所有的level shifter cells, isolation cells 以及power/ ground nets.
verifyPowerVia
VerifyPowerVia 可做許多power-rail overlap check 用以找出power-grid missing vias. 例如要check非相鄰層之間是否缺少via 可以用命令 "verifyPowerVia -layerRange{bottomLayer topLayer}" 或 "verifyPowerVia-stackedVia".
If you create stripes with 'set2set' distance and want to be able to flag violations where the power rails do not connect to the power stripe within the 'set2set' distance or specified area, you can use the following newverifyPowerViaparameters:
-
-layer_rail:Specifies the power rail layer to be checked.
-
-layer_stripe:Specifies the stripe layer list to be checked.
-
-search_range:Specifies a rectangle area of XY dimension. There should be a valid connection from power rail to power stripe in the specified area.
-
-stripe_rule:Specifies in microns thecenter-to-center spacingdistance for the power via, which is on the power rail.
示例:如下命令check layer M2 跟 M3之間power rails 的連接關(guān)系, 如果這個(gè)VIA center-to-center 距離大于 17um,工具就會(huì)報(bào) violation 并且標(biāo)注對(duì)應(yīng)的 power rail wires.
Note: 文中涉及的三個(gè)命令,在Innovus 的命令文檔中都可以找到更詳細(xì)的描述,用戶可以根據(jù)自己的需求加對(duì)應(yīng)的option 做對(duì)應(yīng)的check.
總結(jié)
以上是生活随笔為你收集整理的Innovus中如何验证低功耗设计的全部?jī)?nèi)容,希望文章能夠幫你解決所遇到的問題。
- 上一篇: 刷新DNS解析缓存+追踪+域名解析命令