瑞萨RCAR-M3N高温死机问题
溫度策略,超過120℃,將會觸發(fā)關(guān)機(jī)
[ ?577.564512] thermal thermal_zone2: critical temperature reached (121 C), shutting down
[ ?577.572646] thermal thermal_zone2: critical temperature reached (120 C), shutting down
[ ?577.588781] reboot: Failed to start orderly shutdown: forcing the issue
[ ?577.625296] PVR_K: ?2119: SysDevicePrePowerState: start
[ ?577.653827] PVR_K: ?2119: DisableClocks: start
? 577.726784] PVR_K: ?2119: SysDevicePostPowerState: start
[ ?577.759366] reboot: Power down
120℃的設(shè)置位置:
"arch/arm64/boot/dts/renesas/r8a77965.dtsi"
sensor_thermal2: sensor-thermal2 {
? ? polling-delay-passive = <250>;
? ? polling-delay = <0>;
? ? thermal-sensors = <&tsc 1>;
? ? sustainable-power = <2439>;
? ? trips {
? ? ? ? sensor2_crit: sensor2-crit {
? ? ? ? ? ? temperature = <120000>;
? ? ? ? ? ? hysteresis = <1000>;
? ? ? ? ? ? type = "critical";
? ? ? ? };
? ? };
};
總結(jié)
以上是生活随笔為你收集整理的瑞萨RCAR-M3N高温死机问题的全部內(nèi)容,希望文章能夠幫你解決所遇到的問題。
- 上一篇: 瑞星杀毒软件、奇虎360杀毒软件、360
- 下一篇: 解决MathType插入公式后多出空格问