Xilinx Vitis 2020.2 Ubuntu 设置串口连接ZCU102开发板
前提環境:開發板上電后,JTAG模式啟動,SD卡已燒寫系統文件,JTAG 和UART已連接主機
?
首先 下載驅動Linux_3.x.x_4.x.x_VCP_Driver_Source.zip,網址https://www.silabs.com/developers/usb-to-uart-bridge-vcp-drivers
編譯安裝
make cp cp210x.ko /lib/modules/<kernel-version>/kernel/drivers/usb/serial insmod /lib/modules/<kernel-version/kernel/drivers/usb/serial/usbserial.ko insmod cp210x.ko然后Terminal中執行 dmesg | grep tty
dmesg | grep tty
[??? 0.077306] printk: console [tty0] enabled
[?? 11.762257] usb 1-9: FTDI USB Serial Device converter now attached to ttyUSB0
[?? 11.765588] usb 1-10: cp210x converter now attached to ttyUSB1
[?? 11.766179] usb 1-10: cp210x converter now attached to ttyUSB2
[?? 11.766630] usb 1-10: cp210x converter now attached to ttyUSB3
[?? 11.767095] usb 1-10: cp210x converter now attached to ttyUSB4
[ 2874.130151] cp210x ttyUSB1: cp210x converter now disconnected from ttyUSB1
[ 2874.130635] cp210x ttyUSB2: cp210x converter now disconnected from ttyUSB2
[ 2874.131046] cp210x ttyUSB3: cp210x converter now disconnected from ttyUSB3
[ 2874.131518] cp210x ttyUSB4: cp210x converter now disconnected from ttyUSB4
[ 2875.849944] ftdi_sio ttyUSB0: FTDI USB Serial Device converter now disconnected from ttyUSB0
[ 2935.341174] usb 1-10: cp210x converter now attached to ttyUSB0
[ 2935.342065] usb 1-10: cp210x converter now attached to ttyUSB1
[ 2935.342928] usb 1-10: cp210x converter now attached to ttyUSB2
[ 2935.343950] usb 1-10: cp210x converter now attached to ttyUSB3
[ 2938.964674] usb 1-9: FTDI USB Serial Device converter now attached to ttyUSB4
?
然后執行 ls -l /dev/ttyUSB*
ls -l /dev/ttyUSB*
crw-rw-rw- 1 root dialout 188, 0 11月 28 13:02 /dev/ttyUSB0
crw-rw---- 1 root dialout 188, 1 11月 28 13:02 /dev/ttyUSB1
crw-rw---- 1 root dialout 188, 2 11月 28 13:02 /dev/ttyUSB2
crw-rw---- 1 root dialout 188, 3 11月 28 13:02 /dev/ttyUSB3
crw-rw---- 1 root dialout 188, 4 11月 28 13:02 /dev/ttyUSB4
?
在Vitis中點擊 Window, Show view如下圖,不知道為啥軟件界面不能截屏
打開Vitis Serial Terimal自帶的串口工具
點擊右上角的加號,Port輸入框輸入/dev/ttyUSB0,Connected to: Serial(/dev/ttyUSB0,115200,0,8)提示連接成功
(輸入ttyUSB0不行,輸入別的也不行,都試過了)
這樣就可以執行開發板上的命令了。類似于遠程連接ssh了
?
總結
以上是生活随笔為你收集整理的Xilinx Vitis 2020.2 Ubuntu 设置串口连接ZCU102开发板的全部內容,希望文章能夠幫你解決所遇到的問題。
- 上一篇: python正则匹配ABAC型词语