mysql的cpu飙升到500_[MySQLCPU]线上飙升800%,load达到12的解决过程
接到報警通知,負載過高,達到800%,load也過高,有11了。
MySQL版本為5.6.12-log
1 top 之后,確實是mysqld進程占據了所有資源。
2 查看error日志,無任何異常
3 show eninge innodb status\G,沒有死鎖信息。
4 show full processlist;
沒有耗時非常大的慢sql再跑。看并發,當前的線程總數量也才30個左右。
5 查看iostat,讀寫正常。
到底是什么問題呢?查看slow log,發現如下SQL,頻繁執行,耗時在5秒之間,explain有Using join buffer (Block Nested Loop)
mysql> explain selectweb_page_object.web_page_object_id,-> web_page_object.object_id,-> web_div_name,web_page_object.position_sort,web_page_object.end_time,om1.label,om1.file,jump_url,om2.label as label1,om2.file asfile1-> from web_page_div,web_page_object,object_media as om1,object_media asom2-> where web_page_div.id=web_page_object.web_page_div_id-> and web_page_object.object_media_id=om1.object_media_id-> and web_page_div.web_page_id=1200
-> and if(web_page_object.object_media_id1=0,-> web_page_object.object_media_id=om2.object_media_id,-> web_page_object.object_media_id1=om2.object_media_id)->
-> and '2014-05-01 15:09:49'>=start_time-> and '2014-05-01 15:09:49'<=end_time->
-> and object_status=0
-> order by web_page_div.id,web_page_object.position_sort;
+----+-------------+-----------------+--------+-----------------------+---------+---------+-------------------------------------------+-------+----------------------------------------------------+
| id | select_type | table | type | possible_keys | key | key_len | ref | rows | Extra |
+----+-------------+-----------------+--------+-----------------------+---------+---------+-------------------------------------------+-------+----------------------------------------------------+
| 1 | SIMPLE | web_page_object | ALL | object_media_id_index | NULL | NULL | NULL | 51165 | Using where; Using temporary; Using filesort |
| 1 | SIMPLE | web_page_div | eq_ref | PRIMARY,idx | PRIMARY | 4 | db_jiapin.web_page_object.web_page_div_id | 1 | Using where |
| 1 | SIMPLE | om1 | eq_ref | PRIMARY | PRIMARY | 4 | db_jiapin.web_page_object.object_media_id | 1 | Using where |
| 1 | SIMPLE | om2 | ALL | NULL | NULL | NULL | NULL | 74759 | Using where; Using join buffer (Block Nested Loop) |
+----+-------------+-----------------+--------+-----------------------+---------+---------+-------------------------------------------+-------+----------------------------------------------------+
Using join buffer (Block Nested Loop)
看SQL是where后面的if判斷引起的,拆分if之后,就正常了,SQL耗時不到0.1秒。數據庫load也降下來了。
還記錄以前碰到的
(Block Nested Loop)的案例是 join后面的on條件里面有or判斷。
也會引起Block Nested Loop,導致數據庫負載過高。
總結
以上是生活随笔為你收集整理的mysql的cpu飙升到500_[MySQLCPU]线上飙升800%,load达到12的解决过程的全部內容,希望文章能夠幫你解決所遇到的問題。
- 上一篇: Linux单用户能做什么,Linux单用
- 下一篇: java流的传递方式是_java中数据的