四种DCOM错误的区别,0x80080005 0x800706be 0x80010105 0x
生活随笔
收集整理的這篇文章主要介紹了
四种DCOM错误的区别,0x80080005 0x800706be 0x80010105 0x
小編覺得挺不錯的,現(xiàn)在分享給大家,幫大家做個參考.
四種DCOM錯誤的區(qū)別
Differences between the following DCOM error
0x80080005
0x800706be
0x80010105
0x800706ba 0x80080005:CO_E_Server_Exec_Failure
Server execution failed It is usually quite clear: COM (really, RPCSS) tried to launch a particular server process and either it failed to start, or it died after being started without registering (via CoRegisterClassObject), or it failed to register within a timely manner after being started (usually ~2 minutes are allowed, but the time limit can vary by server type). Repro:比如你有一個程序叫做SimpleDCOM.exe,作為DCOM服務(wù)器一切運行正常。如果你把notepad.exe改名為SimpleDCOM.exe,替代掉原先的文件,客戶端在調(diào)用DCOM的時候就會出這個錯。SOX050427700068
0x800706be:PRC_S_CALL_FAILED
The remote procedure call failed. The Server crashes before finishing the call. Repro:重現(xiàn)這個問題很簡單。在DCOM的方法中顯示一個MessageBox。在dismiss掉這個MessageBox,讓DCOM call返回以前,從任務(wù)管理器殺死DCOM Server,然后客戶端就會看到這個錯了。 0x80010105:RPC_E_SERVERFAULT
The server threw an exception Very straight forward, the server throws an exception. Repro:DCOM方法中直接拋出一個C++ exception就可以重現(xiàn)這個問題。聰明的你可能會問,為啥米C++ exception不會導(dǎo)致DCOM Server crash吶,那是因為: "Normally, an exception that happens in a DCOM server during execution of a method call is caught by an exception handler in OLE32.DLL, and the method call returns RPC_E_SERVERFAULT." 如果要改變這個行為,可以參考IgnoreServerExceptions這個注冊表鍵:
http://support.microsoft.com/kb/198623/en-us
0x800706ba:RPC_S_SERVER_UNAVAILABLE
The PRC server is unavaliable The server stub is disconnected. Repro:在客戶段new一個DCOM object, 暫時不使用。然后重任務(wù)管理器中殺死DCOM Server, 然后調(diào)用這個DCOM object的方法,錯誤就出來了 http://eparg.spaces.live.com/blog/cns!59BFC22C0E7E1A76!2168.entry
Differences between the following DCOM error
0x80080005
0x800706be
0x80010105
0x800706ba 0x80080005:CO_E_Server_Exec_Failure
Server execution failed It is usually quite clear: COM (really, RPCSS) tried to launch a particular server process and either it failed to start, or it died after being started without registering (via CoRegisterClassObject), or it failed to register within a timely manner after being started (usually ~2 minutes are allowed, but the time limit can vary by server type). Repro:比如你有一個程序叫做SimpleDCOM.exe,作為DCOM服務(wù)器一切運行正常。如果你把notepad.exe改名為SimpleDCOM.exe,替代掉原先的文件,客戶端在調(diào)用DCOM的時候就會出這個錯。SOX050427700068
0x800706be:PRC_S_CALL_FAILED
The remote procedure call failed. The Server crashes before finishing the call. Repro:重現(xiàn)這個問題很簡單。在DCOM的方法中顯示一個MessageBox。在dismiss掉這個MessageBox,讓DCOM call返回以前,從任務(wù)管理器殺死DCOM Server,然后客戶端就會看到這個錯了。 0x80010105:RPC_E_SERVERFAULT
The server threw an exception Very straight forward, the server throws an exception. Repro:DCOM方法中直接拋出一個C++ exception就可以重現(xiàn)這個問題。聰明的你可能會問,為啥米C++ exception不會導(dǎo)致DCOM Server crash吶,那是因為: "Normally, an exception that happens in a DCOM server during execution of a method call is caught by an exception handler in OLE32.DLL, and the method call returns RPC_E_SERVERFAULT." 如果要改變這個行為,可以參考IgnoreServerExceptions這個注冊表鍵:
http://support.microsoft.com/kb/198623/en-us
0x800706ba:RPC_S_SERVER_UNAVAILABLE
The PRC server is unavaliable The server stub is disconnected. Repro:在客戶段new一個DCOM object, 暫時不使用。然后重任務(wù)管理器中殺死DCOM Server, 然后調(diào)用這個DCOM object的方法,錯誤就出來了 http://eparg.spaces.live.com/blog/cns!59BFC22C0E7E1A76!2168.entry
轉(zhuǎn)載于:https://www.cnblogs.com/zjoch/p/4367573.html
總結(jié)
以上是生活随笔為你收集整理的四种DCOM错误的区别,0x80080005 0x800706be 0x80010105 0x的全部內(nèi)容,希望文章能夠幫你解決所遇到的問題。
- 上一篇: 陨石多少钱啊?